Parameter Unit PG1 PG2 PG3
RF Peak Power approx MW 2,9 3,9 5,5
RF average Power approx kW 3,5 3,8 4,0
modulator Peak Power MW 5,8 7,8 14,8
modulator average Power kW 7,1 7,5 8,0
Pulse voltage kV 48 52 56
Pulse current A 120 150 265
Pulse repetition Frequency range Hz 30-300 30-400 30-500
Max PRF at max Peak & average P Hz 300 270 180
Pulse Length (top) ìs 4 3,5 3
Flatness % ± 1 ± 1 ± 1
Repeatability % ± 0,2 ± 0,2 ± 0,2

Solid State Pulse Generator

The Generator is for driving PEF chambers processing pumpable liquids for example juices, sludge and other pump able materials.

Tags: